Selling Fluke 199B – We Buy New Used 199B (‘s) Top Dollar Paid!

If you’re looking to Sell Fluke 199B ScopeMeter 200 MHz Oscilloscope 199

ScopeMeter® 190 Series : All this power in your hand!

The ScopeMeter 190 Series has specifications you typically only find on high-end bench oscilloscopes. They offer up to 200 MHz bandwidth for capturing high frequency signals, as found in today’s state-of-the-art electronics, 2.5 GS/s real-time sampling and advanced memory and triggering functions. They’re rugged, compact and battery powered.

 

General Features:

  • Dual-input – 200, 100 or 60 MHz bandwidth
  • Up to 2.5 GS/s real-time sampling per input
  • Choice between a high resolution Color display (190C Series) or Black & White display (190B Series)
  • High waveform resolution of 3,000 datapoints per channel (NEW)
  • Connect-and-View™ automatic triggering and a full range of manual trigger modes
  • Frequency Spectrum Analysis using FFT (190C) (NEW)
  • Digital Persistence for analyzing complex dynamic waveforms like on an analog scope
  • Fast display update rate for seeing dynamic behavior instantaneously
  • Automatic capture and replay of 100 screens
  • 27,500 points per input record length using ScopeRecord™ mode
  • TrendPlot™ paperless chart recorder for trend analysis up to 22 days
  • Up to 1000 V independently floating isolated inputs
  • Waveform reference for visual comparisons and automatic pass/fail testing of waveforms
  • Vpwm function for motor drive and frequency inverter applications.
  • 1000 V CAT II and 600 V CAT III safety certified
  • Four hours rechargeable Ni-MH battery pack

See what’s really happening

High sampling rate gives you the required resolution for detailed signal analysis

With a maximum real-time sampling rate of 2.5 GS/s per input, you can see what really happens, with 400 ps resolution. Both inputs have their own digitizer, so you can simultaneously acquire two waveforms and analyze them with the highest resolution and detail. If an anomaly flashes by on the screen, just press the Replay button to see it again. And thanks to the wider screen, you will always see a 12 divisions time-window – giving a far better overview of what’s happening both before and after the trigger event!
Deeper waveform acquisition memory (NEW)

Thanks to the deeper memory, very small parts of the waveform can be studied in full detail using ‘zoom’.

The waveform memory of all oscilloscopes in both the 190B and 190C Series has been enlarged to allow as many as 3000 samples per channel to be acquired. This is 1800 samples more than before, giving much greater waveform resolution. You can use the ZOOM function to find tiny details in a long waveform, for example, the color burst in a video signal or a single impulse in a complex data-stream. All models also allow the high-resolution waveforms to be transferred to a PC for later detailed analysis using FlukeView ScopeMeter software.
Easier identification of traces, everywhere

Color traces and the high contrast display make signal identification easy

The full-color display makes identification of individual waveforms easier, particularly when displaying large amplitude or multiple overlapping waveforms on screen. On-screen color labels, measurements and warnings are clearly linked to specific waveforms. The bright, high contrast display allows for clear reading under varying light conditions. And still a 4 hour battery operation time is assured!
See dynamic signal behavior instantaneously

Digital persistence mode gives analog scope like display of complex and modulated signals

The Digital Persistence uses multiple intensity levels and user selectable decay time -it’s as if you’re looking at the display of an analog, real time oscilloscope! The fast display update rate that’s a standard on all models reveals signal changes instantaneously, useful for instance when making adjustments to a system under test.
Advanced trigger modes

Pulse width triggering allows you to find anomalies like missing pulses

A wide choice of automatic and manual trigger modes gives you the flexibility to capture just about any signal you’ll encounter. Connect-and-View™ triggering is ideal for fast and easy checking of multiple test-points. The manual modes include time delay, video and pulse-width triggering. A fully isolated external trigger input is included for troubleshooting time relationships between two input signals synchronized to a third signal.
(NEW)

Dual-slope triggering used to capture the eyepattern on a digital datastream.

Two new modes – ‘n-cycle triggering’ and ‘dual-slope triggering’ – have been added to the Fluke 190C Series to help you isolate the phenomena of interest. N-cycle triggering ensures you get a stable ‘live’ image of a signal, for example, in frequency dividers and clocked (synchronous) digital systems, or to synchronize on bursts of pulses. Dual-slope triggering enables the oscilloscopes to trigger on both rising and falling edges alike. This means that any edge in the signal will act as trigger event and initiate a new waveform acquisition, a most useful capability when making eye-patterns from digital data-streams, or in conjunction with single-shot phenomena.
Automatic capture and replay of 100 screens

Scope users know how frustrating it is to see a one-time anomaly flash by, never to be seen again. Not with the ScopeMeter 190 Series! Now you can look back in time with a touch of the replay button. In normal use, the instrument continuously memorizes the last 100 screens. Each time a new screen is acquired, the oldest is discarded. At any moment you can “freeze” the last 100 screens and scroll through picture-by-picture or replay as a ‘live’ animation. Cursors can be used for further analysis. Or you can use the advanced trigger capabilities to capture up to 100 specific events. Two sets of 100 captured screens with individual time stamps can be stored for later recall or download to a PC.
Deep memory for high-resolution ScopeRecord™

Use the 27,500 points memory of the ScopeRecord mode and zoom in for maximum detail

The ScopeRecord memory stores 27,500 points per input or more, for high resolution recording of events up to 48 hours, and captures fast intermit-tents and glitches as short as 50 ns. This continuous roll mode stores, for example, events like motion profiles, UPS-, power supply- and motor start-ups. All models also have a ‘Stop-on-Trigger’ in the ScopeRecord mode. This allows the ScopeMeter to store waveform data until the instrument is triggered or until a repetitive trigger signal is interrupted. This way, the instrument will, for example, automatically recognize a power failure and store the waveform data preceding it. And with 100 x zoom, you can look at the smallest details, like individual power cycles. Two of these 27,500 point recordings can be stored for later analysis.
Measure from mV to kV – fully isolated and safely!

Use Vpwm and measure effective voltage on motor drive and frequency inverter outputs

The ScopeMeter 190 Series have three independently floating isolated inputs. While conventional oscilloscopes can only make measurements referenced to the line power ground, measurements on each of the Fluke ScopeMeter 190 Series inputs can be referenced to a different “low” level. This enables measurements in mixed circuits having different ground references, and also eliminates the risk of accidental ground short circuits. All inputs are safety certified for measurements in 1000 V CAT II and 600 V CAT III environments. And the standard probes cover a wide application range from mV to kV, making the ScopeMeter 190 Series ideal for micro-electronics to electrical power applications.
Analysis power

A wide variety of measurements can be made on either Channel A or B

For analysis of waveforms, ScopeRecord and TrendPlot recordings, the ScopeMeter 190 Series feature 30 automatic measurements, plus cursors, zoom and a real-time clock. The analysis can be made directly or later when back in the office. Up to 2 recordings and 10 scope screens can be stored for analysis, print-out or download to a PC.

Buying, Selling, Trading Fluke 199B


Frequency Spectrum Analysis (NEW)

Frequency Spectrum shows an overview of frequencies contained in a signal.

All 190C Color ScopeMeters now include Frequency Spectrum Analysis functionality based on Fast Fourier Transformation (FFT) analysis as a standard feature. This makes it possible for you to identify the individual frequency components contained in a signal. The spectrum analysis function is also handy to reveal the effects of vibration, signal interference or crosstalk. An automatic window function assures optimal windowing, although you may manually select your preferred time window.
Waveform Pass / Fail Testing

Pass/Fail testing of actual signal against a reference template

‘Waveform reference’ allows an acquired trace to be stored and designated ‘reference trace’ for visual comparisons, or it can be used as the reference for automatic ‘Pass / Fail’ testing (190C). Up to 100 individually matching (‘Pass’) or non-matching (‘Fail’) waveforms can be stored in the replay memory, allowing you to monitor your system’s behavior over a long period of time, without the need for you to attend!
Cursor-limited automatic measurement (NEW)

The rms-value of the noise is measured on the part of the waveform enclosed by the cursors.

Automatic power and Vrms-measurements can now be performed on a specific, user identified portion of the waveform using the cursors of the Fluke 190C to define the time-window of interest. In this way, the Color ScopeMeter can measure the power within a specified time span, or the rms-value of a voltage during a dedicated period of time.
… and there is more

  • Variable gain on channel A helps you compare signals on the two inputs. All inputs are safety certified for measurements in 1000 V CAT II and 600 V
  • The Vpwm measurement is for measuring the effective RMS output voltage of variable speed motor drives and frequency inverters.
  • Medical applications: For use on Medical Imaging Equipment and on High-Resolution Video systems, an optional instrument configuration is available for the Fluke 190 Series that supports measurement of


Use TrendPlot™ to help find intermittents, fast

Cursors and zoom help you analyze the captured TrendPlot

The toughest faults to find are those that happen only once in a while: intermittents. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. You may not be around to see it – your Fluke ScopeMeter will. In this “paperless recorder” mode, you can plot the minimum and maximum peak values and average over time – up to 22 days. The two inputs can plot any combination of voltage, current, temperature, frequency and phase – with time and date stamp -to help lead you to the cause of those faults quickly.
FlukeView® Software for documenting, archiving and analysis FlukeView® for Windows® helps you get more out of your ScopeMeter by:

  • Documenting – transfer waveforms, screens and measurement data from the ScopeMeter to a PC. Print or import the data into your report
  • Add user text to individual ScopeMeter settings – providing guidance to the operator when recalling a set-up.
  • Archiving – create a library of waveforms with your comments for easy reference and comparison. Store complete Replay cycles for analysis of waveform changes. Store complete memory content of the Scop
  • Waveform Compare – store reference waveforms on the PC, or send a reference back to the ScopeMeter for waveform comparison and “Pass/Fail” testing.
  • Analysis – use cursors, perform spectrum analysis or export data to other analysis programs. ScopeMeter test tools are connected to a PC via an optically-isolated RS-232 interface cable.

Specifications

Bandwidth: 200 MHz
Real-time sample rate: 2.5 GS/s
Inputs and digitizers: 2 plus external / DMM input
Independently floating isolated inputs: Up to 1000 V between inputs, references and ground
Timebase range: 5 ns – 2 min/div; 10 ns – 2 min/div (192B)
Input sensitivity: 5 mV-100 V/div
Glitch capture: 50 ns (5 µs/div – 1 min/div)
Scope measurements: Cursor: 7; Automatic: 30
Maximum record length: ScopeRecord mode: 27,500 pts per input; Scope mode: 3,000 pts per input
Memory: Screens: 10; Setups: 10
Display: 144 mm full monochrome LCD with fast update rate

If you’re selling your Fluke 199B please fill out form on the right hand side of page.

To Download Data Sheet Click here

Selling Fluke 199 – We Buy New Used 199 (‘s) Top Dollar Paid!

If you’re looking to Sell Fluke 199 ScopeMeter 200 MHz Oscilloscope

ScopeMeter® 190 Series : All this power in your hand!

The ScopeMeter 190 Series has specifications you typically only find on high-end bench oscilloscopes. They offer up to 200 MHz bandwidth for capturing high frequency signals, as found in today’s state-of-the-art electronics, 2.5 GS/s real-time sampling and advanced memory and triggering functions. They’re rugged, compact and battery powered.

 

General Features:

  • Dual-input – 200, 100 or 60 MHz bandwidth
  • Up to 2.5 GS/s real-time sampling per input
  • Choice between a high resolution Color display (190C Series) or Black & White display (190B Series)
  • High waveform resolution of 3,000 datapoints per channel (NEW)
  • Connect-and-View™ automatic triggering and a full range of manual trigger modes
  • Frequency Spectrum Analysis using FFT (190C) (NEW)
  • Digital Persistence for analyzing complex dynamic waveforms like on an analog scope
  • Fast display update rate for seeing dynamic behavior instantaneously
  • Automatic capture and replay of 100 screens
  • 27,500 points per input record length using ScopeRecord™ mode
  • TrendPlot™ paperless chart recorder for trend analysis up to 22 days
  • Up to 1000 V independently floating isolated inputs
  • Waveform reference for visual comparisons and automatic pass/fail testing of waveforms
  • Vpwm function for motor drive and frequency inverter applications.
  • 1000 V CAT II and 600 V CAT III safety certified
  • Four hours rechargeable Ni-MH battery pack

See what’s really happening

High sampling rate gives you the required resolution for detailed signal analysis

With a maximum real-time sampling rate of 2.5 GS/s per input, you can see what really happens, with 400 ps resolution. Both inputs have their own digitizer, so you can simultaneously acquire two waveforms and analyze them with the highest resolution and detail. If an anomaly flashes by on the screen, just press the Replay button to see it again. And thanks to the wider screen, you will always see a 12 divisions time-window – giving a far better overview of what’s happening both before and after the trigger event!
Deeper waveform acquisition memory (NEW)

Thanks to the deeper memory, very small parts of the waveform can be studied in full detail using ‘zoom’.

The waveform memory of all oscilloscopes in both the 190B and 190C Series has been enlarged to allow as many as 3000 samples per channel to be acquired. This is 1800 samples more than before, giving much greater waveform resolution. You can use the ZOOM function to find tiny details in a long waveform, for example, the color burst in a video signal or a single impulse in a complex data-stream. All models also allow the high-resolution waveforms to be transferred to a PC for later detailed analysis using FlukeView ScopeMeter software.
Easier identification of traces, everywhere

Color traces and the high contrast display make signal identification easy

The full-color display makes identification of individual waveforms easier, particularly when displaying large amplitude or multiple overlapping waveforms on screen. On-screen color labels, measurements and warnings are clearly linked to specific waveforms. The bright, high contrast display allows for clear reading under varying light conditions. And still a 4 hour battery operation time is assured!
See dynamic signal behavior instantaneously

Digital persistence mode gives analog scope like display of complex and modulated signals

The Digital Persistence uses multiple intensity levels and user selectable decay time -it’s as if you’re looking at the display of an analog, real time oscilloscope! The fast display update rate that’s a standard on all models reveals signal changes instantaneously, useful for instance when making adjustments to a system under test.
Advanced trigger modes

Pulse width triggering allows you to find anomalies like missing pulses

A wide choice of automatic and manual trigger modes gives you the flexibility to capture just about any signal you’ll encounter. Connect-and-View™ triggering is ideal for fast and easy checking of multiple test-points. The manual modes include time delay, video and pulse-width triggering. A fully isolated external trigger input is included for troubleshooting time relationships between two input signals synchronized to a third signal.
(NEW)

Dual-slope triggering used to capture the eyepattern on a digital datastream.

Two new modes – ‘n-cycle triggering’ and ‘dual-slope triggering’ – have been added to the Fluke 190C Series to help you isolate the phenomena of interest. N-cycle triggering ensures you get a stable ‘live’ image of a signal, for example, in frequency dividers and clocked (synchronous) digital systems, or to synchronize on bursts of pulses. Dual-slope triggering enables the oscilloscopes to trigger on both rising and falling edges alike. This means that any edge in the signal will act as trigger event and initiate a new waveform acquisition, a most useful capability when making eye-patterns from digital data-streams, or in conjunction with single-shot phenomena.
Automatic capture and replay of 100 screens

Scope users know how frustrating it is to see a one-time anomaly flash by, never to be seen again. Not with the ScopeMeter 190 Series! Now you can look back in time with a touch of the replay button. In normal use, the instrument continuously memorizes the last 100 screens. Each time a new screen is acquired, the oldest is discarded. At any moment you can “freeze” the last 100 screens and scroll through picture-by-picture or replay as a ‘live’ animation. Cursors can be used for further analysis. Or you can use the advanced trigger capabilities to capture up to 100 specific events. Two sets of 100 captured screens with individual time stamps can be stored for later recall or download to a PC.
Deep memory for high-resolution ScopeRecord™

Use the 27,500 points memory of the ScopeRecord mode and zoom in for maximum detail

The ScopeRecord memory stores 27,500 points per input or more, for high resolution recording of events up to 48 hours, and captures fast intermit-tents and glitches as short as 50 ns. This continuous roll mode stores, for example, events like motion profiles, UPS-, power supply- and motor start-ups. All models also have a ‘Stop-on-Trigger’ in the ScopeRecord mode. This allows the ScopeMeter to store waveform data until the instrument is triggered or until a repetitive trigger signal is interrupted. This way, the instrument will, for example, automatically recognize a power failure and store the waveform data preceding it. And with 100 x zoom, you can look at the smallest details, like individual power cycles. Two of these 27,500 point recordings can be stored for later analysis.

Buying, Selling, Trading Fluke 199


Measure from mV to kV – fully isolated and safely!

Use Vpwm and measure effective voltage on motor drive and frequency inverter outputs

The ScopeMeter 190 Series have three independently floating isolated inputs. While conventional oscilloscopes can only make measurements referenced to the line power ground, measurements on each of the Fluke ScopeMeter 190 Series inputs can be referenced to a different “low” level. This enables measurements in mixed circuits having different ground references, and also eliminates the risk of accidental ground short circuits. All inputs are safety certified for measurements in 1000 V CAT II and 600 V CAT III environments. And the standard probes cover a wide application range from mV to kV, making the ScopeMeter 190 Series ideal for micro-electronics to electrical power applications.
Analysis power

A wide variety of measurements can be made on either Channel A or B

For analysis of waveforms, ScopeRecord and TrendPlot recordings, the ScopeMeter 190 Series feature 30 automatic measurements, plus cursors, zoom and a real-time clock. The analysis can be made directly or later when back in the office. Up to 2 recordings and 10 scope screens can be stored for analysis, print-out or download to a PC.
Frequency Spectrum Analysis (NEW)

Frequency Spectrum shows an overview of frequencies contained in a signal.

All 190C Color ScopeMeters now include Frequency Spectrum Analysis functionality based on Fast Fourier Transformation (FFT) analysis as a standard feature. This makes it possible for you to identify the individual frequency components contained in a signal. The spectrum analysis function is also handy to reveal the effects of vibration, signal interference or crosstalk. An automatic window function assures optimal windowing, although you may manually select your preferred time window.
Waveform Pass / Fail Testing

Pass/Fail testing of actual signal against a reference template

‘Waveform reference’ allows an acquired trace to be stored and designated ‘reference trace’ for visual comparisons, or it can be used as the reference for automatic ‘Pass / Fail’ testing (190C). Up to 100 individually matching (‘Pass’) or non-matching (‘Fail’) waveforms can be stored in the replay memory, allowing you to monitor your system’s behavior over a long period of time, without the need for you to attend!
Cursor-limited automatic measurement (NEW)

The rms-value of the noise is measured on the part of the waveform enclosed by the cursors.

Automatic power and Vrms-measurements can now be performed on a specific, user identified portion of the waveform using the cursors of the Fluke 190C to define the time-window of interest. In this way, the Color ScopeMeter can measure the power within a specified time span, or the rms-value of a voltage during a dedicated period of time.
… and there is more

  • Variable gain on channel A helps you compare signals on the two inputs. All inputs are safety certified for measurements in 1000 V CAT II and 600 V
  • The Vpwm measurement is for measuring the effective RMS output voltage of variable speed motor drives and frequency inverters.
  • Medical applications: For use on Medical Imaging Equipment and on High-Resolution Video systems, an optional instrument configuration is available for the Fluke 190 Series that supports measurement of


Use TrendPlot™ to help find intermittents, fast

Cursors and zoom help you analyze the captured TrendPlot

The toughest faults to find are those that happen only once in a while: intermittents. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. You may not be around to see it – your Fluke ScopeMeter will. In this “paperless recorder” mode, you can plot the minimum and maximum peak values and average over time – up to 22 days. The two inputs can plot any combination of voltage, current, temperature, frequency and phase – with time and date stamp -to help lead you to the cause of those faults quickly.
FlukeView® Software for documenting, archiving and analysis FlukeView® for Windows® helps you get more out of your ScopeMeter by:

If you’re selling your Fluke 199 please fill out form on the right hand side of page.

  • Documenting – transfer waveforms, screens and measurement data from the ScopeMeter to a PC. Print or import the data into your report
  • Add user text to individual ScopeMeter settings – providing guidance to the operator when recalling a set-up.
  • Archiving – create a library of waveforms with your comments for easy reference and comparison. Store complete Replay cycles for analysis of waveform changes. Store complete memory content of the Scop
  • Waveform Compare – store reference waveforms on the PC, or send a reference back to the ScopeMeter for waveform comparison and “Pass/Fail” testing.
  • Analysis – use cursors, perform spectrum analysis or export data to other analysis programs. ScopeMeter test tools are connected to a PC via an optically-isolated RS-232 interface cable.

Specifications

Bandwidth: 200 MHz
Real-time sample rate: 2.5 GS/s
Inputs and digitizers: 2 plus external / DMM input
Independently floating isolated inputs: Up to 1000 V between inputs, references and ground
Timebase range: 5 ns – 2 min/div; 10 ns – 2 min/div (192B)
Input sensitivity: 5 mV-100 V/div
Glitch capture: 50 ns (5 µs/div – 1 min/div)
Scope measurements: Cursor: 7; Automatic: 30
Maximum record length: ScopeRecord mode: 27,500 pts per input; Scope mode: 3,000 pts per input
Memory: Screens: 10; Setups: 10
Display: 144 mm full monochrome LCD with fast update rate

Selling Fluke 196BM – We Buy New Used 196BM (‘s) Top Dollar Paid!

If you’re looking to Sell Fluke 196BM ScopeMeter Medical Oscilloscope

The Fluke 190 Series Medical ScopeMeters are high-performance oscilloscopes for the most demanding applications when servicing medical imaging equipment and video systems. Based upon the Fluke 190B / 190C Series ScopeMeters, the Fluke Medical ScopeMeter offers measurement capabilities optimized for servicing medical equipment in the following modalities: X-ray, MRI, Nuclear Medicine and Ultrasound.

  • Dual input – 100 MHz bandwidth
  • Choice of color or monochrome versions
  • Up to 1 GS/s real-time sampling per input
  • mAs current-over-time measurement
  • Connect-and-View™ automatic triggering, a full range of manual trigger modes plus external triggering
  • Video triggering with line selector for standard and high-resolution video systems
  • Smart averaging
  • Selectable persistence mode
  • 27,500 points per input record length using ScopeRecord™ mode
  • Automatic capture and replay of 100 screens
  • Automatic waveform measurements
  • Four hours rechargeable NiMH battery pack
  • 1,000 V CAT II and 600 V CAT III safety certified
  • Up to 1,000 V independently floating isolated inputs
  • Includes a 5,000 counts true-rms multimeter and a TrendPlot™ paperless recorder

Specifications

  • Bandwidth: 100 MHz
  • Real-time sample rate: 1 GS/s
  • Inputs and digitizers: 2 plus external / DMM input
  • Independently floating isolated inputs: Up to 1000 V between inputs, references and ground
  • Timebase range: 5 ns – 2 min/div / 10 ns – 2 min/div (192B)
  • Input sensitivity: 5 mV-100 V/div
  • Trigger types: Connect-and-View™, Free Run, Single Shot, Edge, Delay, Video, Selectable pulse width and External
  • Glitch capture: 50 ns (5 µs/div – 1 min/div)
  • Scope measurements: Cursor: 7 / Automatic:30
  • Maximum record length: ScopeRecord mode:27,500 pts per input / Scope mode: 3,000 pts per input
  • Memory: Screens: 10 / Setups: 10
  • Display: 144 mm full monochrome LCD with fast update rate
  • Waveform Compare: Waveform reference only

Buying, Selling, Trading Fluke 196BM

Environmental Specifications

  • Operating Temperature: 0 to 50ºC
  • Storage Temperature: -20 to +60°C
  • Operating Altitude: 3,000 m

Safety Specifications

  • Electrical Safety: 1,000V CAT II/600V CAT III (EN61010-1)

Mechanical & General Specifications

  • Size: 256 x 169 x 64 mm
  • Weight: 2.0 kg
  • Battery Life: NiMH:4 hrs
  • RS-232 Interface: Optically isolated via optional PM9080/OC4USB for interfacing to Printer or PC

If you’re selling your Fluke 196BM please fill out form on the right hand side of page.

Selling Fluke 196C – We Buy New Used 196C (‘s) Top Dollar Paid!

If you’re looking to Sell Fluke 196C ScopeMeter Color Oscilloscope

Features & Applications:

The Fluke 196/003 ScopeMeter high-performance oscilloscope offers specifications usually found on top-end bench instruments. With up to 100 MHz bandwidth and 1 GS/s real-time sampling and a deep memory of 27,500 points per input, it’s ideal for engineers who need the full capabilities of a high-performance oscilloscope in a handheld, battery-powered instrument.

Features:

  • Dual-input – 100 MHz bandwidth
  • Up to 1 GS/s real time sampling per input
  • Digital Persistence for analyzing complex dynamic waveforms like on an analog scope (190)
  • Large, high resolution color or monochrome screen
  • Connect and view automatic triggering and a full range of manual trigger modes
  • Fast display update rate for seeing dynamic behavior instantaneously
  • Automatic capture and replay of 100 screens
  • 27,500 points per input record length using ScopeRecord mode
  • TrendPlot paperless chart recorder for trend analysis up to 22 days
  • UP to 1000 V independently floating isolated inputs
  • 1000 V CAT II and 600 V CAT III safety certified
  • Five hours rechargeable Ni-MH battery pack

Buying, Selling, Trading Fluke 196C

If you’re selling your Fluke 196C please fill out form on the right hand side of page.

Selling Fluke 196B – We Buy New Used 196B (‘s) Top Dollar Paid!

If you’re looking to Sell Fluke 196B ScopeMeter Handheld Oscilloscope

Features & Applications:

The Fluke 196/003 ScopeMeter high-performance oscilloscope offers specifications usually found on top-end bench instruments. With up to 100 MHz bandwidth and 1 GS/s real-time sampling and a deep memory of 27,500 points per input, it’s ideal for engineers who need the full capabilities of a high-performance oscilloscope in a handheld, battery-powered instrument.

Features:

  • Dual-input – 100 MHz bandwidth
  • Up to 1 GS/s real time sampling per input
  • Digital Persistence for analyzing complex dynamic waveforms like on an analog scope (190)
  • Large, high resolution color or monochrome screen
  • Connect and view automatic triggering and a full range of manual trigger modes
  • Fast display update rate for seeing dynamic behavior instantaneously
  • Automatic capture and replay of 100 screens
  • 27,500 points per input record length using ScopeRecord mode
  • TrendPlot paperless chart recorder for trend analysis up to 22 days
  • UP to 1000 V independently floating isolated inputs
  • 1000 V CAT II and 600 V CAT III safety certified
  • Five hours rechargeable Ni-MH battery pack

 

Buying, Selling, Trading Fluke 196B

If you’re selling your Fluke 196B please fill out form on the right hand side of page.

Selling Fluke 196 – We Buy New Used 196 (‘s) Top Dollar Paid!

If you’re looking to Sell Fluke 196 ScopeMeter Handheld Oscilloscope

Features & Applications:

The Fluke 196/003 ScopeMeter high-performance oscilloscope offers specifications usually found on top-end bench instruments. With up to 100 MHz bandwidth and 1 GS/s real-time sampling and a deep memory of 27,500 points per input, it’s ideal for engineers who need the full capabilities of a high-performance oscilloscope in a handheld, battery-powered instrument.

 

Features:

  • Dual-input – 100 MHz bandwidth
  • Up to 1 GS/s real time sampling per input
  • Digital Persistence for analyzing complex dynamic waveforms like on an analog scope (190)
  • Large, high resolution color or monochrome screen
  • Connect and view automatic triggering and a full range of manual trigger modes
  • Fast display update rate for seeing dynamic behavior instantaneously
  • Automatic capture and replay of 100 screens
  • 27,500 points per input record length using ScopeRecord mode
  • TrendPlot paperless chart recorder for trend analysis up to 22 days
  • UP to 1000 V independently floating isolated inputs
  • 1000 V CAT II and 600 V CAT III safety certified
  • Five hours rechargeable Ni-MH battery pack

Buying, Selling, Trading Fluke 196

If you’re selling your Fluke 196 please fill out form on the right hand side of page.

Selling Fluke 192C – We Buy New Used 192C (‘s) Top Dollar Paid!

If you’re looking to Sell Fluke 192C ScopeMeter 500MS/s Dual-Input 60MHz

The ScopeMeter 190 Series has specifications you typically only find on high-end bench oscilloscopes. They offer up to 200 MHz bandwidth for capturing high frequency signals, as found in today’s state-of-the-art electronics, 2.5 GS/s real-time sampling and advanced memory and triggering functions. They’re rugged, compact and battery powered.

General Features:

  • Dual-input – 200, 100 or 60 MHz bandwidth
  • Up to 2.5 GS/s real-time sampling per input
  • Choice between a high resolution Color display (190C Series) or Black & White display (190B Series)
  • High waveform resolution of 3,000 datapoints per channel (NEW)
  • Connect-and-View™ automatic triggering and a full range of manual trigger modes
  • Frequency Spectrum Analysis using FFT (190C) (NEW)
  • Digital Persistence for analyzing complex dynamic waveforms like on an analog scope
  • Fast display update rate for seeing dynamic behavior instantaneously
  • Automatic capture and replay of 100 screens
  • 27,500 points per input record length using ScopeRecord™ mode
  • TrendPlot™ paperless chart recorder for trend analysis up to 22 days
  • Up to 1000 V independently floating isolated inputs
  • Waveform reference for visual comparisons and automatic pass/fail testing of waveforms
  • Vpwm function for motor drive and frequency inverter applications.
  • 1000 V CAT II and 600 V CAT III safety certified
  • Four hours rechargeable Ni-MH battery pack

See what’s really happening

High sampling rate gives you the required resolution for detailed signal analysis

With a maximum real-time sampling rate of 2.5 GS/s per input, you can see what really happens, with 400 ps resolution. Both inputs have their own digitizer, so you can simultaneously acquire two waveforms and analyze them with the highest resolution and detail. If an anomaly flashes by on the screen, just press the Replay button to see it again. And thanks to the wider screen, you will always see a 12 divisions time-window – giving a far better overview of what’s happening both before and after the trigger event!

Deeper waveform acquisition memory (NEW)

Thanks to the deeper memory, very small parts of the waveform can be studied in full detail using ‘zoom’.

The waveform memory of all oscilloscopes in both the 190B and 190C Series has been enlarged to allow as many as 3000 samples per channel to be acquired. This is 1800 samples more than before, giving much greater waveform resolution. You can use the ZOOM function to find tiny details in a long waveform, for example, the color burst in a video signal or a single impulse in a complex data-stream. All models also allow the high-resolution waveforms to be transferred to a PC for later detailed analysis using FlukeView ScopeMeter software.

Easier identification of traces, everywhere

Color traces and the high contrast display make signal identification easy

The full-color display makes identification of individual waveforms easier, particularly when displaying large amplitude or multiple overlapping waveforms on screen. On-screen color labels, measurements and warnings are clearly linked to specific waveforms. The bright, high contrast display allows for clear reading under varying light conditions. And still a 4 hour battery operation time is assured!

See dynamic signal behavior instantaneously

Digital persistence mode gives analog scope like display of complex and modulated signals

The Digital Persistence uses multiple intensity levels and user selectable decay time -it’s as if you’re looking at the display of an analog, real time oscilloscope! The fast display update rate that’s a standard on all models reveals signal changes instantaneously, useful for instance when making adjustments to a system under test.

Advanced trigger modes

Pulse width triggering allows you to find anomalies like missing pulses

A wide choice of automatic and manual trigger modes gives you the flexibility to capture just about any signal you’ll encounter. Connect-and-View™ triggering is ideal for fast and easy checking of multiple test-points. The manual modes include time delay, video and pulse-width triggering. A fully isolated external trigger input is included for troubleshooting time relationships between two input signals synchronized to a third signal.

(NEW)

Dual-slope triggering used to capture the eyepattern on a digital datastream.

Two new modes – ‘n-cycle triggering’ and ‘dual-slope triggering’ – have been added to the Fluke 190C Series to help you isolate the phenomena of interest. N-cycle triggering ensures you get a stable ‘live’ image of a signal, for example, in frequency dividers and clocked (synchronous) digital systems, or to synchronize on bursts of pulses. Dual-slope triggering enables the oscilloscopes to trigger on both rising and falling edges alike.
This means that any edge in the signal will act as trigger event and initiate a new waveform acquisition, a most useful capability when making eye-patterns from digital data-streams, or in conjunction with single-shot phenomena.

Automatic capture and replay of 100 screens

Scope users know how frustrating it is to see a one-time anomaly flash by, never to be seen again. Not with the ScopeMeter 190 Series! Now you can look back in time with a touch of the replay button. In normal use, the instrument continuously memorizes the last 100 screens. Each time a new screen is acquired, the oldest is discarded. At any moment you can “freeze” the last 100 screens and scroll through picture-by-picture or replay as a ‘live’ animation. Cursors can be used for further analysis. Or you can use the advanced trigger capabilities to capture up to 100 specific events. Two sets of 100 captured screens with individual time stamps can be stored for later recall or download to a PC.

Deep memory for high-resolution ScopeRecord™

Use the 27,500 points memory of the ScopeRecord mode and zoom in for maximum detail

The ScopeRecord memory stores 27,500 points per input or more, for high resolution recording of events up to 48 hours, and captures fast intermit-tents and glitches as short as 50 ns. This continuous roll mode stores, for example, events like motion profiles, UPS-, power supply- and motor start-ups. All models also have a ‘Stop-on-Trigger’ in the ScopeRecord mode. This allows the ScopeMeter to store waveform data until the instrument is triggered or until a repetitive trigger signal is interrupted. This way, the instrument will, for example, automatically recognize a power failure and store the waveform data preceding it. And with 100 x zoom, you can look at the smallest details, like individual power cycles. Two of these 27,500 point recordings can be stored for later analysis.

 

Buying, Selling, Trading Fluke 192C

Measure from mV to kV – fully isolated and safely!

Use Vpwm and measure effective voltage on motor drive and frequency inverter outputs

The ScopeMeter 190 Series have three independently floating isolated inputs. While conventional oscilloscopes can only make measurements referenced to the line power ground, measurements on each of the Fluke ScopeMeter 190 Series inputs can be referenced to a different “low” level. This enables measurements in mixed circuits having different ground references, and also eliminates the risk of accidental ground short circuits. All inputs are safety certified for measurements in 1000 V CAT II and 600 V CAT III environments. And the standard probes cover a wide application range from mV to kV, making the ScopeMeter 190 Series ideal for micro-electronics to electrical power applications.

Analysis power

A wide variety of measurements can be made on either Channel A or B

For analysis of waveforms, ScopeRecord and TrendPlot recordings, the ScopeMeter 190 Series feature 30 automatic measurements, plus cursors, zoom and a real-time clock. The analysis can be made directly or later when back in the office. Up to 2 recordings and 10 scope screens can be stored for analysis, print-out or download to a PC.

Frequency Spectrum Analysis (NEW)

All 190C Color ScopeMeters now include Frequency Spectrum Analysis functionality based on Fast Fourier Transformation (FFT) analysis as a standard feature. This makes it possible for you to identify the individual frequency components contained in a signal. The spectrum analysis function is also handy to reveal the effects of vibration, signal interference or crosstalk. An automatic window function assures optimal windowing, although you may manually select your preferred time window.

Waveform Pass / Fail Testing‘Waveform reference’ allows an acquired trace to be stored and designated ‘reference trace’ for visual comparisons, or it can be used as the reference for automatic ‘Pass / Fail’ testing (190C). Up to 100 individually matching (‘Pass’) or non-matching (‘Fail’) waveforms can be stored in the replay memory, allowing you to monitor your system’s behavior over a long period of time, without the need for you to attend!

Cursor-limited automatic measurement (NEW)Automatic power and Vrms-measurements can now be performed on a specific, user identified portion of the waveform using the cursors of the Fluke 190C to define the time-window of interest. In this way, the Color ScopeMeter can measure the power within a specified time span, or the rms-value of a voltage during a dedicated period of time.

… and there is more

Frequency Spectrum shows an overview of frequencies contained in a signal.
Pass/Fail testing of actual signal against a reference template
The rms-value of the noise is measured on the part of the waveform enclosed by the cursors.
    • Variable gain on channel A helps you compare signals on the two inputs. All inputs are safety certified for measurements in 1000 V CAT II and 600 V
    • The Vpwm measurement is for measuring the effective RMS output voltage of variable speed motor drives and frequency inverters.
    • The high-sensitivity setting of 2 mV/div allows for measurements on low-level signals, that are hard to make with the average oscilloscope.
    • Medical applications: For use on Medical Imaging Equipment and on High-Resolution Video systems, an optional instrument configuration is available for the Fluke 190 Series that supports measurement of



Use TrendPlot™ to help find intermittents, fast

Cursors and zoom help you analyze the captured TrendPlot

The toughest faults to find are those that happen only once in a while: intermittents. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. You may not be around to see it – your Fluke ScopeMeter will. In this “paperless recorder” mode, you can plot the minimum and maximum peak values and average over time – up to 22 days. The two inputs can plot any combination of voltage, current, temperature, frequency and phase – with time and date stamp -to help lead you to the cause of those faults quickly.

FlukeView® Software for documenting, archiving and analysis
FlukeView® for Windows® helps you get more out of your ScopeMeter by:

If you’re selling your Fluke 192C please fill out form on the right hand side of page.

Selling Fluke 192B – We Buy New Used 192B (‘s) Top Dollar Paid!

If you’re looking to Sell Fluke 192B ScopeMeter 500MS/s Dual-Input 60MHz

The ScopeMeter 190 Series has specifications you typically only find on high-end bench oscilloscopes. They offer up to 200 MHz bandwidth for capturing high frequency signals, as found in today’s state-of-the-art electronics, 2.5 GS/s real-time sampling and advanced memory and triggering functions. They’re rugged, compact and battery powered.

General Features:

  • Dual-input – 200, 100 or 60 MHz bandwidth
  • Up to 2.5 GS/s real-time sampling per input
  • Choice between a high resolution Color display (190C Series) or Black & White display (190B Series)
  • High waveform resolution of 3,000 datapoints per channel (NEW)
  • Connect-and-View™ automatic triggering and a full range of manual trigger modes
  • Frequency Spectrum Analysis using FFT (190C) (NEW)
  • Digital Persistence for analyzing complex dynamic waveforms like on an analog scope
  • Fast display update rate for seeing dynamic behavior instantaneously
  • Automatic capture and replay of 100 screens
  • 27,500 points per input record length using ScopeRecord™ mode
  • TrendPlot™ paperless chart recorder for trend analysis up to 22 days
  • Up to 1000 V independently floating isolated inputs
  • Waveform reference for visual comparisons and automatic pass/fail testing of waveforms
  • Vpwm function for motor drive and frequency inverter applications.
  • 1000 V CAT II and 600 V CAT III safety certified
  • Four hours rechargeable Ni-MH battery pack

 


See what’s really happening

High sampling rate gives you the required resolution for detailed signal analysis

With a maximum real-time sampling rate of 2.5 GS/s per input, you can see what really happens, with 400 ps resolution. Both inputs have their own digitizer, so you can simultaneously acquire two waveforms and analyze them with the highest resolution and detail. If an anomaly flashes by on the screen, just press the Replay button to see it again. And thanks to the wider screen, you will always see a 12 divisions time-window – giving a far better overview of what’s happening both before and after the trigger event!
Deeper waveform acquisition memory (NEW)

Thanks to the deeper memory, very small parts of the waveform can be studied in full detail using ‘zoom’.

The waveform memory of all oscilloscopes in both the 190B and 190C Series has been enlarged to allow as many as 3000 samples per channel to be acquired. This is 1800 samples more than before, giving much greater waveform resolution. You can use the ZOOM function to find tiny details in a long waveform, for example, the color burst in a video signal or a single impulse in a complex data-stream. All models also allow the high-resolution waveforms to be transferred to a PC for later detailed analysis using FlukeView ScopeMeter software.
Easier identification of traces, everywhere

Color traces and the high contrast display make signal identification easy

The full-color display makes identification of individual waveforms easier, particularly when displaying large amplitude or multiple overlapping waveforms on screen. On-screen color labels, measurements and warnings are clearly linked to specific waveforms. The bright, high contrast display allows for clear reading under varying light conditions. And still a 4 hour battery operation time is assured!

See dynamic signal behavior instantaneously

The Digital Persistence uses multiple intensity levels and user selectable decay time -it’s as if you’re looking at the display of an analog, real time oscilloscope! The fast display update rate that’s a standard on all models reveals signal changes instantaneously, useful for instance when making adjustments to a system under test.
Advanced trigger modes

Pulse width triggering allows you to find anomalies like missing pulses

A wide choice of automatic and manual trigger modes gives you the flexibility to capture just about any signal you’ll encounter. Connect-and-View™ triggering is ideal for fast and easy checking of multiple test-points. The manual modes include time delay, video and pulse-width triggering. A fully isolated external trigger input is included for troubleshooting time relationships between two input signals synchronized to a third signal.
(NEW)

Dual-slope triggering used to capture the eyepattern on a digital datastream.

Two new modes – ‘n-cycle triggering’ and ‘dual-slope triggering’ – have been added to the Fluke 190C Series to help you isolate the phenomena of interest. N-cycle triggering ensures you get a stable ‘live’ image of a signal, for example, in frequency dividers and clocked (synchronous) digital systems, or to synchronize on bursts of pulses. Dual-slope triggering enables the oscilloscopes to trigger on both rising and falling edges alike. This means that any edge in the signal will act as trigger event and initiate a new waveform acquisition, a most useful capability when making eye-patterns from digital data-streams, or in conjunction with single-shot phenomena.
Automatic capture and replay of 100 screens

Scope users know how frustrating it is to see a one-time anomaly flash by, never to be seen again. Not with the ScopeMeter 190 Series! Now you can look back in time with a touch of the replay button. In normal use, the instrument continuously memorizes the last 100 screens. Each time a new screen is acquired, the oldest is discarded. At any moment you can “freeze” the last 100 screens and scroll through picture-by-picture or replay as a ‘live’ animation. Cursors can be used for further analysis. Or you can use the advanced trigger capabilities to capture up to 100 specific events. Two sets of 100 captured screens with individual time stamps can be stored for later recall or download to a PC.
Deep memory for high-resolution ScopeRecord™The ScopeRecord memory stores 27,500 points per input or more, for high resolution recording of events up to 48 hours, and captures fast intermit-tents and glitches as short as 50 ns. This continuous roll mode stores, for example, events like motion profiles, UPS-, power supply- and motor start-ups. All models also have a ‘Stop-on-Trigger’ in the ScopeRecord mode. This allows the ScopeMeter to store waveform data until the instrument is triggered or until a repetitive trigger signal is interrupted. This way, the instrument will, for example, automatically recognize a power failure and store the waveform data preceding it. And with 100 x zoom, you can look at the smallest details, like individual power cycles. Two of these 27,500 point recordings can be stored for later analysis.
Measure from mV to kV – fully isolated and safely!The ScopeMeter 190 Series have three independently floating isolated inputs. While conventional oscilloscopes can only make measurements referenced to the line power ground, measurements on each of the Fluke ScopeMeter 190 Series inputs can be referenced to a different “low” level. This enables measurements in mixed circuits having different ground references, and also eliminates the risk of accidental ground short circuits. All inputs are safety certified for measurements in 1000 V CAT II and 600 V CAT III environments. And the standard probes cover a wide application range from mV to kV, making the ScopeMeter 190 Series ideal for micro-electronics to electrical power applications.
Analysis powerFor analysis of waveforms, ScopeRecord and TrendPlot recordings, the ScopeMeter 190 Series feature 30 automatic measurements, plus cursors, zoom and a real-time clock. The analysis can be made directly or later when back in the office. Up to 2 recordings and 10 scope screens can be stored for analysis, print-out or download to a PC.
Frequency Spectrum Analysis (NEW)All 190C Color ScopeMeters now include Frequency Spectrum Analysis functionality based on Fast Fourier Transformation (FFT) analysis as a standard feature. This makes it possible for you to identify the individual frequency components contained in a signal. The spectrum analysis function is also handy to reveal the effects of vibration, signal interference or crosstalk. An automatic window function assures optimal windowing, although you may manually select your preferred time window.
Waveform Pass / Fail Testing‘Waveform reference’ allows an acquired trace to be stored and designated ‘reference trace’ for visual comparisons, or it can be used as the reference for automatic ‘Pass / Fail’ testing (190C). Up to 100 individually matching (‘Pass’) or non-matching (‘Fail’) waveforms can be stored in the replay memory, allowing you to monitor your system’s behavior over a long period of time, without the need for you to attend!
Cursor-limited automatic measurement (NEW)Automatic power and Vrms-measurements can now be performed on a specific, user identified portion of the waveform using the cursors of the Fluke 190C to define the time-window of interest. In this way, the Color ScopeMeter can measure the power within a specified time span, or the rms-value of a voltage during a dedicated period of time.
… and there is more

Buying, Selling, Trading Fluke 192B

  • Variable gain on channel A helps you compare signals on the two inputs. All inputs are safety certified for measurements in 1000 V CAT II and 600 V
  • The Vpwm measurement is for measuring the effective RMS output voltage of variable speed motor drives and frequency inverters.
  • The high-sensitivity setting of 2 mV/div allows for measurements on low-level signals, that are hard to make with the average oscilloscope.
  • Medical applications: For use on Medical Imaging Equipment and on High-Resolution Video systems, an optional instrument configuration is available for the Fluke 190 Series that supports measurement of


Use TrendPlot™ to help find intermittents, fastThe toughest faults to find are those that happen only once in a while: intermittents. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. You may not be around to see it – your Fluke ScopeMeter will. In this “paperless recorder” mode, you can plot the minimum and maximum peak values and average over time – up to 22 days. The two inputs can plot any combination of voltage, current, temperature, frequency and phase – with time and date stamp -to help lead you to the cause of those faults quickly.
FlukeView® Software for documenting, archiving and analysis FlukeView® for Windows® helps you get more out of your ScopeMeter by:

Use the 27,500 points memory of the ScopeRecord mode and zoom in for maximum detail
Use Vpwm and measure effective voltage on motor drive and frequency inverter outputs
A wide variety of measurements can be made on either Channel A or B
Frequency Spectrum shows an overview of frequencies contained in a signal.
Pass/Fail testing of actual signal against a reference template
The rms-value of the noise is measured on the part of the waveform enclosed by the cursors.
Cursors and zoom help you analyze the captured TrendPlot
  • Documenting – transfer waveforms, screens and measurement data from the ScopeMeter to a PC. Print or import the data into your report
  • Add user text to individual ScopeMeter settings – providing guidance to the operator when recalling a set-up.
  • Archiving – create a library of waveforms with your comments for easy reference and comparison. Store complete Replay cycles for analysis of waveform changes. Store complete memory content of the Scop
  • Waveform Compare – store reference waveforms on the PC, or send a reference back to the ScopeMeter for waveform comparison and “Pass/Fail” testing.
  • Analysis – use cursors, perform spectrum analysis or export data to other analysis programs. ScopeMeter test tools are connected to a PC via an optically-isolated RS-232 interface cable.

Specifications

Bandwidth: 60 MHz
Real-time sample rate: 500 MS/s
Inputs and digitizers: 2 plus external / DMM input
Independently floating isolated inputs: Up to 1000 V between inputs, references and ground
Timebase range: 5 ns – 2 min/div; 10 ns – 2 min/div (192B)
Input sensitivity: 5 mV-100 V/div
Glitch capture: 50 ns (5 µs/div – 1 min/div) 
Scope measurements:
Cursor: 7; Automatic: 30
Maximum record length: ScopeRecord mode: 27,500 pts per input; Scope mode: 3,000 pts per input
Memory: Screens: 10; Setups: 10
Display: 144 mm full monochrome LCD with fast update rate

If you’re selling your Fluke 99B please fill out form on the right hand side of page

Selling Fluke 192 – We Buy New Used 192 (‘s) Top Dollar Paid!

If you’re looking to Sell Fluke 192 ScopeMeter 500MS/s Dual-Input 60MHz

The ScopeMeter 190 Series has specifications you typically only find on high-end bench oscilloscopes. They offer up to 200 MHz bandwidth for capturing high frequency signals, as found in today’s state-of-the-art electronics, 2.5 GS/s real-time sampling and advanced memory and triggering functions. They’re rugged, compact and battery powered.

General Features:

  • Dual-input – 200, 100 or 60 MHz bandwidth
  • Up to 2.5 GS/s real-time sampling per input
  • Choice between a high resolution Color display (190C Series) or Black & White display (190B Series)
  • High waveform resolution of 3,000 datapoints per channel (NEW)
  • Connect-and-View™ automatic triggering and a full range of manual trigger modes
  • Frequency Spectrum Analysis using FFT (190C) (NEW)
  • Digital Persistence for analyzing complex dynamic waveforms like on an analog scope
  • Fast display update rate for seeing dynamic behavior instantaneously
  • Automatic capture and replay of 100 screens
  • 27,500 points per input record length using ScopeRecord™ mode
  • TrendPlot™ paperless chart recorder for trend analysis up to 22 days
  • Up to 1000 V independently floating isolated inputs
  • Waveform reference for visual comparisons and automatic pass/fail testing of waveforms
  • Vpwm function for motor drive and frequency inverter applications.
  • 1000 V CAT II and 600 V CAT III safety certified
  • Four hours rechargeable Ni-MH battery pack

 


See what’s really happening

High sampling rate gives you the required resolution for detailed signal analysis

With a maximum real-time sampling rate of 2.5 GS/s per input, you can see what really happens, with 400 ps resolution. Both inputs have their own digitizer, so you can simultaneously acquire two waveforms and analyze them with the highest resolution and detail. If an anomaly flashes by on the screen, just press the Replay button to see it again. And thanks to the wider screen, you will always see a 12 divisions time-window – giving a far better overview of what’s happening both before and after the trigger event!
Deeper waveform acquisition memory (NEW)

Thanks to the deeper memory, very small parts of the waveform can be studied in full detail using ‘zoom’.

The waveform memory of all oscilloscopes in both the 190B and 190C Series has been enlarged to allow as many as 3000 samples per channel to be acquired. This is 1800 samples more than before, giving much greater waveform resolution. You can use the ZOOM function to find tiny details in a long waveform, for example, the color burst in a video signal or a single impulse in a complex data-stream. All models also allow the high-resolution waveforms to be transferred to a PC for later detailed analysis using FlukeView ScopeMeter software.
Easier identification of traces, everywhere

Color traces and the high contrast display make signal identification easy

The full-color display makes identification of individual waveforms easier, particularly when displaying large amplitude or multiple overlapping waveforms on screen. On-screen color labels, measurements and warnings are clearly linked to specific waveforms. The bright, high contrast display allows for clear reading under varying light conditions. And still a 4 hour battery operation time is assured!
See dynamic signal behavior instantaneously

Digital persistence mode gives analog scope like display of complex and modulated signals

The Digital Persistence uses multiple intensity levels and user selectable decay time -it’s as if you’re looking at the display of an analog, real time oscilloscope! The fast display update rate that’s a standard on all models reveals signal changes instantaneously, useful for instance when making adjustments to a system under test.
Advanced trigger modes

Pulse width triggering allows you to find anomalies like missing pulses

A wide choice of automatic and manual trigger modes gives you the flexibility to capture just about any signal you’ll encounter. Connect-and-View™ triggering is ideal for fast and easy checking of multiple test-points. The manual modes include time delay, video and pulse-width triggering. A fully isolated external trigger input is included for troubleshooting time relationships between two input signals synchronized to a third signal.
(NEW)

Dual-slope triggering used to capture the eyepattern on a digital datastream.

Two new modes – ‘n-cycle triggering’ and ‘dual-slope triggering’ – have been added to the Fluke 190C Series to help you isolate the phenomena of interest. N-cycle triggering ensures you get a stable ‘live’ image of a signal, for example, in frequency dividers and clocked (synchronous) digital systems, or to synchronize on bursts of pulses. Dual-slope triggering enables the oscilloscopes to trigger on both rising and falling edges alike. This means that any edge in the signal will act as trigger event and initiate a new waveform acquisition, a most useful capability when making eye-patterns from digital data-streams, or in conjunction with single-shot phenomena.
Automatic capture and replay of 100 screens

Scope users know how frustrating it is to see a one-time anomaly flash by, never to be seen again. Not with the ScopeMeter 190 Series! Now you can look back in time with a touch of the replay button. In normal use, the instrument continuously memorizes the last 100 screens. Each time a new screen is acquired, the oldest is discarded. At any moment you can “freeze” the last 100 screens and scroll through picture-by-picture or replay as a ‘live’ animation. Cursors can be used for further analysis. Or you can use the advanced trigger capabilities to capture up to 100 specific events. Two sets of 100 captured screens with individual time stamps can be stored for later recall or download to a PC.
Deep memory for high-resolution ScopeRecord™

Use the 27,500 points memory of the ScopeRecord mode and zoom in for maximum detail

The ScopeRecord memory stores 27,500 points per input or more, for high resolution recording of events up to 48 hours, and captures fast intermit-tents and glitches as short as 50 ns. This continuous roll mode stores, for example, events like motion profiles, UPS-, power supply- and motor start-ups. All models also have a ‘Stop-on-Trigger’ in the ScopeRecord mode. This allows the ScopeMeter to store waveform data until the instrument is triggered or until a repetitive trigger signal is interrupted. This way, the instrument will, for example, automatically recognize a power failure and store the waveform data preceding it. And with 100 x zoom, you can look at the smallest details, like individual power cycles. Two of these 27,500 point recordings can be stored for later analysis.

Buying, Selling, Trading Fluke 192


Measure from mV to kV – fully isolated and safely!

Use Vpwm and measure effective voltage on motor drive and frequency inverter outputs

The ScopeMeter 190 Series have three independently floating isolated inputs. While conventional oscilloscopes can only make measurements referenced to the line power ground, measurements on each of the Fluke ScopeMeter 190 Series inputs can be referenced to a different “low” level. This enables measurements in mixed circuits having different ground references, and also eliminates the risk of accidental ground short circuits. All inputs are safety certified for measurements in 1000 V CAT II and 600 V CAT III environments. And the standard probes cover a wide application range from mV to kV, making the ScopeMeter 190 Series ideal for micro-electronics to electrical power applications.
Analysis power

A wide variety of measurements can be made on either Channel A or B

For analysis of waveforms, ScopeRecord and TrendPlot recordings, the ScopeMeter 190 Series feature 30 automatic measurements, plus cursors, zoom and a real-time clock. The analysis can be made directly or later when back in the office. Up to 2 recordings and 10 scope screens can be stored for analysis, print-out or download to a PC.
Frequency Spectrum Analysis (NEW)All 190C Color ScopeMeters now include Frequency Spectrum Analysis functionality based on Fast Fourier Transformation (FFT) analysis as a standard feature. This makes it possible for you to identify the individual frequency components contained in a signal. The spectrum analysis function is also handy to reveal the effects of vibration, signal interference or crosstalk. An automatic window function assures optimal windowing, although you may manually select your preferred time window.

Waveform Pass / Fail Testing‘Waveform reference’ allows an acquired trace to be stored and designated ‘reference trace’ for visual comparisons, or it can be used as the reference for automatic ‘Pass / Fail’ testing (190C). Up to 100 individually matching (‘Pass’) or non-matching (‘Fail’) waveforms can be stored in the replay memory, allowing you to monitor your system’s behavior over a long period of time, without the need for you to attend!
Cursor-limited automatic measurement (NEW)Automatic power and Vrms-measurements can now be performed on a specific, user identified portion of the waveform using the cursors of the Fluke 190C to define the time-window of interest. In this way, the Color ScopeMeter can measure the power within a specified time span, or the rms-value of a voltage during a dedicated period of time.
… and there is more

  • Variable gain on channel A helps you compare signals on the two inputs. All inputs are safety certified for measurements in 1000 V CAT II and 600 V
  • The Vpwm measurement is for measuring the effective RMS output voltage of variable speed motor drives and frequency inverters.
  • The high-sensitivity setting of 2 mV/div allows for measurements on low-level signals, that are hard to make with the average oscilloscope.
  • Medical applications: For use on Medical Imaging Equipment and on High-Resolution Video systems, an optional instrument configuration is available for the Fluke 190 Series that supports measurement of

Use TrendPlot™ to help find intermittents, fastt faults to find are those that happen only once in a while: intermittents. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. You may not be around to see it – your Fluke ScopeMeter will. In this “paperless recorder” mode, you can plot the minimum and maximum peak values and average over time – up to 22 days. The two inputs can plot any combination of voltage, current, temperature, frequency and phase – with time and date stamp -to help lead you to the cause of those faults quickly.
FlukeView® Software for documenting, archiving and analysis FlukeView® for Windows® helps you get more out of your ScopeMeter by:

  • Documenting – transfer waveforms, screens and measurement data from the ScopeMeter to a PC. Print or import the data into your report
  • Add user text to individual ScopeMeter settings – providing guidance to the operator when recalling a set-up.
  • Archiving – create a library of waveforms with your comments for easy reference and comparison. Store complete Replay cycles for analysis of waveform changes. Store complete memory content of the Scop
  • Waveform Compare – store reference waveforms on the PC, or send a reference back to the ScopeMeter for waveform comparison and “Pass/Fail” testing.
  • Analysis – use cursors, perform spectrum analysis or export data to other analysis programs. ScopeMeter test tools are connected to a PC via an optically-isolated RS-232 interface cable.

SpecificationsBandwidth: 60 MHz
Real-time sample rate: 500 MS/s
Inputs and digitizers: 2 plus external / DMM input
Independently floating isolated inputs: Up to 1000 V between inputs, references and ground
Timebase range: 5 ns – 2 min/div; 10 ns – 2 min/div (192B)
Input sensitivity: 5 mV-100 V/div
Glitch capture: 50 ns (5 µs/div – 1 min/div)
Scope measurements: Cursor: 7; Automatic: 30
Maximum record length: ScopeRecord mode: 27,500 pts per input; Scope mode: 3,000 pts per input
Memory: Screens: 10; Setups: 10
Display: 144 mm full monochrome LCD with fast update rateIf you’re selling your Fluke 192 please fill out form on the right hand side of page.

Frequency Spectrum shows an overview of frequencies contained in a signal.
Pass/Fail testing of actual signal against a reference template
The rms-value of the noise is measured on the part of the waveform enclosed by the cursors.
Cursors and zoom help you analyze the captured TrendPlot

Selling Fluke 123 – We Buy New Used 123 (‘s) Top Dollar Paid!

If you’re looking to Sell FLUKE 123 Industrial ScopeMeter 20MHz Dual Trace

The compact ScopeMeter 123 is the rugged solution for industrial troubleshooting and installation applications. It’s a truly integrated test tool, with oscilloscope, multimeter and “paperless” recorder in one affordable, easy-to-use instrument. Find fast answers to problems in machinery, instrumentation, control and power systems.

 

Features:

  • Fluke 123: 20 MHz Bandwidth, 25 MS/s
  • Two Channels, Scope or DMM mode
  • 5 mV to 500 V/div
  • 60 s to 20 ns/div
  • NTSC, PAL, SECAM video triggering
  • True-RMS DMM with 5000 count / 0.5% accuracy
  • 2 Channel TrendPlot for recording trends and intermittents
  • Optical RS-232 port for connection to PC’s
  • Connect-And-View allows for quick hands-off operation
  • Improved Battery Charge Process
  • Lightweight (2.5 lb./1.2 kg.)

Buying, Selling, Trading FLUKE 123
If you’re selling your FLUKE 123 please fill out form on the right hand side of page.